Jetall GPU JTL90D3

Request More Information

Category:

Jetall GPU JTL90D3 Specifications:

Engine:

  • Perkins 1104D-E44TAG2, 111 kW, 1800 RPM
  • 4-stroke, 4 cylinders, inline. 148 HP.
  • 12 VDC battery system
  • Low oil pressure shutdown
  • Intake air restriction indication
  • Electronic governor system
  • Automatic cold weather start assists system.

Generator:

  • Rating: 90 kVA at 0.8 PF, 400 Hz, 200 Volt L/L Adjustable +/- 10–15%
  • 3 Phase, 4 wire Wye connected, grounded neutral, revolving field, brushless, self-cooling, insulation class H.

Overload:

  • 125% rated load for 10 minutes.

Regulation:

  • Voltage Regulation: +/- 1% no load to full load

Protection:

  • Meets MIL-STD-704F and MIL-STD-704E
  • Over voltage: instantaneous disconnect of load at 180 volts L-N, inverse time delay down to 126 volts in 2 seconds
  • Under voltage: disconnects output below 100 volts L-N in 7 seconds
  • Over frequency: disconnects output above 420Hz in 5 seconds
  • Under frequency: disconnects output below 370Hz in 7 seconds
  • Frequency Transient Recovery test meets SAE-APR 5015A

DC Rectifier:

  • Rectifier Kit for 28.5VDC with current limiting, 800-amp continuous load and 2200 peak Starting current, Output cable, 30 feet.

Finish:

  • Powder Coat provides excellent resistance, flexibility, adhesion, plus resistance to chemical agents such as glycol, skydrol and Jet A
  • Standard color is high gloss White

Displays / Instrumentation:

Engine

  • Meters: coolant temperature, RPM, hour meter, oil pressure, Voltmeter, Fuel Quantity, Fault indications
  • Indicator Lights: engine circuit on, air cleaner restriction, high coolant temperature, low oil pressure, engine stop delay action, and low fuel.
  • Switches: Engine start / stop, panel lights
  • Delayed shutdown for turbocharger protection

Generator & Rectifier

  • Meters: frequency, ammeter, and voltmeter
  • Indicator Lights: contactors on, over frequency, under frequency, current over load, over voltage, under voltage
  • Switches: meter select, output contactors control, test / reset

Optional Equipment:

  • Indicator beacon, tow and running lights.
  • 28.5 VDC, Rectifier with output 800 Amps continuous, 2,200 Amps peak starting current
  • Cold weather kit 120 or 220 Volt
  • Low fuel warning kit
  • Low coolant level, warning kit400 Hz output cable, 30 feet.

Specifications

Engine

  • Perkins 1104C-44TAG1 opt. at 2,000 RPM
  • Turbocharged 4-stroke, 4 cylinders, 98 KW
  • 12 VDC battery system
  • Low oil pressure shutdown
  • Intake air restriction indication
  • Electronic governor system
  • Automatic cold weather start assists system

Generator

  • Rating: 90 KVA at 0.8 PF, 400 Hz 200 Volt L/L nominal; adjustable ± 10-15%
  • 3 Phase, 4 wire wye connected, grounded neutral, revolving field, brushless, self-cooling, single bearing rectifier assembly, insulation class H

Overload

  • 125% rated load for 10 minutes, 150% for 10 seconds

Regulation

  • Voltage regulation: ± 1% no load to full load

Protection

  • Over-voltage: instantaneous disconnect of load at 180 volts L-N, with inverse time delay down to 126 volts in 2 seconds
  • Under-voltage: disconnects output below 100 volts L-N in 7 seconds
  • Oiver-frequency: disconnects output above 420Hz in 5 seconds
  • Under-frequency: disconnects output below 370Hz in 5 seconds

Finish

  • Powder Coat paint provides excellent weather resistance, flexibility and adhesion, plus a strong resistance to chemical agents such as glycol, Skydrol and Jet A
  • Standard color is High Gloss White
  • Custom colors require a paint chip or swatch for accurate color match

Display / Instrumentation

Engine

  • Meters: coolant temperature, RPM, hour meter, oil pressure, voltmeter, fuel quantity, fault indications
  • Indicator lights: engine circuit on, air cleaner restriction, high coolant temperature, low oil pressure, engine stop delay action, and low fuel
  • Switches: engine start, engine stop, panel lights
  • Delayed shutdown for turbocharger protection

Generator

  • Meters: frequency, ammeter, and voltmeter
  • Indicator lights: contactors on, over-frequency, under-frequency, current overload, over-voltage, under-voltage
  • Switches: meter select, output contactors control, test / reset

Optional Equipment

  • Transformer-Rectifier pack for 28.5VDC with current limiting, 800-amp continuous load and 2,200 peak; output cable, 10 meters
  • AC outlet 110/220 volt, 20 amps kit
  • Indicator beacon, tow and running lights
  • Cold weather kit and battery blanket (120 volt)
  • Second output (120 KVA & 140 KVA models)
  • Low fuel warning kit
  • Low coolant level, warning kit
  • One (1) 10 meter, 400 Hz output cable
  • Two (2) 10 meter, 400 Hz output cables
  • Amber flashing beacon mounted on roof
  • Weatherproofed gauge mounting

Download Specifications