Specifications
Input Power Requirement
- ΑC current, 3 phase, voltage; 208/230/460/575
- Frequency range: 45 to 65 Hz
- Input power factor: 0.96
- Input voltage could be strappable in the field
Output Power Performance: 140 KVA
- 115/200 VAC, 3 phase, 400 Hz ± 0.1%
- Overloads: 100 – 125%, 10 minutes
- 125 – 150%, 30 seconds
- 150 – 200%, 10 seconds
- Load power factor: 0.8 at 100% load
Regulation
- Voltage regulation: < 0.5% for balanced and 30% unbalanced loads
- Phase displacement: 120° ±1° for balanced load 120° ±2° for 30% unbalanced load
- Voltage modulation: < 1%
- Crest factor: 1.414 ±3%
- Transient performance; meets MIL-STD-704F
Protection
- Input; over-/under-voltage overload
- Output; over-/under-voltage
- Over/under frequency transient
- Internal high temperature
- Audible alarm with silencer
- Noise level < 65 DBA at 3 feet
Finish
- Powder coat rather than paint provides superior weather resistance, flexibility and adhesion, plus a strong resistance to chemical agents such as glycol and Skydrol
- Standard color is High Gloss White
Dimensions
- On Casters Cart: L = 82”, W= 44”, H= 56”